IVC-2004PT - 4-Port 10/100TX with PoE+ 1-Port BNC / RJ-11 Industrial Ethernet Extender (-40 ~ 75 degrees C)
Overview
PLANET IVC-2004PT, an Industrial grade Ethernet Extender with PoE supported, is integrated with three advanced technologies: • Extends Ethernet over coaxial cable or phone wire • IEEE 802.3af Power over Ethernet • Industrial wide-ranging operating temperature The IVC-2004PT is designed to utilize the commonly existed coaxial cables or phone wires to extend the UTP Ethernet over 100m distance limitation and transmits both power and data over single Ethernet cable to remote PoE capable devices in heavy industrial demanding environments. IEEE 802.3af Power over Ethernet Integrated The IVC-2004PT provides 4 10/100Mbps copper ports with 4 IEEE 802.3af Power over Ethernet inject interfaces delivered in an IP-30 rugged strong case. Supporting up to 15.4-watt power per port for any remote IEEE 802.3af powered device (PD) such as PoE IP cameras and PoE wireless LAN access point, the IVC-2004PT is an ideal solution to deploying surveillance system, and securing control and wireless service in climatically demanding wide temperature range (-40 to 75 degrees C) environments. Long-reach Ethernet To extend the network distance and provide reliable Ethernet networking in hardened environments, the IVC-2004PT is equipped with one asymmetric / symmetric Ethernet extender port. The extender port can be RJ-11 or BNC connector. Customers can use either BNC or RJ-11 for their network deployment and the IVC-2004PT offers the absolutely fastest data transmission speed up to 99/65Mbps over existing coaxial cable and telephone wire without the need of rewiring. Flexible Combination of Applications The IVC-2004PT helps users to flexibly re-deploy a new local Intranet in the apartment, intelligent transportation systems, building automation, campus and hospitality environment by applying the original network structure without spending extra cost. The IVC-2004PT can be adjusted to Master or Slave mode via a DIP switch. It also can be set up to connect with the other IVC-2004PT or with other PLANET Ethernet extenders -- the IVC-2002, VC-201A and VC-202A. Therefore, users can easily expand the current network structure easily and more flexibly. Environmentally Hardened Design for Industrial PoE Networks The IVC-2004PT provides a high level of immunity against electromagnetic interference and heavy electrical surges typical of environments like plant floors or in curbside traffic control cabinets. The IVC-2004PT is packaged in a compact, IP-30 rugged strong case that allows operating in wide temperature range of -40 to 75 degrees C and installation with either DIN rail or wall mounting for efficient use of cabinet space. |
Key Features
• Integrated address look-up engine, supports 2K absolute MAC addresses• Supports up to 1536 bytes packet size, 802.1Q VLAN tag transparent
• Prevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex)
• Auto-MDI / MDI-X detection and auto-negotiation with half-duplex / full-duplex modes for 10 / 100Base-TX RJ-45 port
• Complies with the IEEE 802.3, IEEE 802.3u Fast Ethernet standard
Data Communication
• Supports ESD 6000V DC Ethernet protection
• Supports EFT 6000V DC protection for power line
• Redundant power design: 48V DC Power Input for PoE
• DIN rail and wall mount design
• -40~75 degree C operating temperature
• IP-30 aluminum metal case protection
Industrial Design
• Remote power feeding up to 100m
• Circuit protection prevents power interference between ports
• Auto-detects powered device (PD)
• Supports PoE Power up to 15.4 watts for each PoE port
• 48V DC Power Input for PoE and 12~ 36V DC for non-PoE devices
• 4 x Ports IEEE 802.3af Power over Ethernet / PSE Standard
IEEE 802.3af PoE
and Downstream signals
• Defines Asymmetric (Band Plan 998) and Symmetric band plans for the transmission of Upstream
• Selectable BNC and RJ-11 mode for the data transmission
• One box design, Master / Slave mode selectable via DIP Switch
• Cost-effective Long-reach Ethernet (LRE) solution
• Ethernet over twisted pair / coaxial
Applications
Industrial Area Department / Workgroup PoE Switch With 4 PoE, in-line power interfaces, the PoE Industrial Ethernet Extender IVC-2004PT can build a power centrally controlled IP phone system, IP camera system, or wireless AP group for the enterprise. For instance, 4 IP cameras or wireless APs can be easily installed around the corner in the company for surveillance demands or build a wireless roaming environment in the offices. Without the power-socket limitation, it makes the installation of cameras or WLAN AP easier and more efficiently. |
Flexible Industrial Extender includes BNC and RJ-11 Connection The IVC-2004PT can operate stably under temperature range from -40 to 75 degrees C so it can be installed in any harsh environment. It is also compatibles with PLANET Ethernet over VDSL2 Converter VC-201A and VC-202A therefore users do not need to spend extra cost to deploy a new local Internet in apartment, hotel, campus and hospitality environment. The network administrator can re-deploy the original network structure with the IVC-2004PT with no further effort. For example, PLANET MC-700, MC-1500 and MC-1500R chassis with the VC-201A and VC-202A inside are set as CPE (Customer Premises Equipment) mode which is placed in the wiring center (MDF room). On the other hand, it connects an IVC-2004PT extender in Master mode by using telephone line or coaxial cable. Therefore, the new network structure can be constructed efficiently. |
Specifications
Hardware Specifications | |
Extender Ports | • Coaxial: 1 BNC, female connector • Phone-Line: 1 RJ-11, female connector |
Ethernet LAN Ports | • 10/100Base-TX: 4 RJ-45, auto-negotiation and auto-MDI / MDI-X • 4 PoE ports (Port1 ~ 4) |
DIP Switch | 4 position DIP switch |
Functionality | • Master / Slave mode select • Selectable BNC and RJ-11 mode • Selectable target Band Plan • Selectable target SNR mode |
Encoding | • DMT (Discrete Multi-Tone) line coding - ITU-T G.997.1 - ITU-T G.993.1 - ITU-T G.993.2 (VDSL2 Profile 17a Support) |
LED Indicators | • System P1 (Green) P2 (Green) Fault (Green) • VDSL2 Master (Green) Slave (Green) ACT (Green) Sync. (Green) • 10/100Mbps port LNK / ACT (Green) PoE In-Use (Orange) |
Cabling | • Ethernet : 10Base-T: 2-pair UTP Cat.3, 4 and 5 up to 100m (328ft) • Ethernet : 100Base-TX: 2-pair UTP Cat.5, 5e and 6 up to 100m (328ft) • Coaxial Cable: –50ohm, RG58A / U, RG58C / U, RG58 / U or equivalent; –75ohm, RG-6 (Distance up to 2.4km) • Twisted-pair telephone wires (AWG24 or better) up to 1.4km |
Dimensions (W x D x H) | 135 x 87.8 x 50 mm |
Weight | 631g |
Power Requirements | 48V DC for PoE Devices 12 ~ 36V DC for Non-PoE Devices Redundant power with polarity reverse protection function |
Power Consumption | 66.4 watts / 226BTU max. (PoE) 5.64 watts / 19.24BTU (non-PoE) |
Installation | DIN rail kit and wall mount ear |
Alarm | Provides one relay output for power failure Alarm relay current carry ability: 1A @ DC 24V |
Performance | |
BNC (Coaxial Cable) | Asymmetric (Download / Upload) 200m -> 99/65Mbps 400m -> 99/64Mbps 600m -> 97/59Mbps 800m -> 94/51Mbps 1000m -> 84/45Mbps 1200m -> 73/37Mbps 1400m -> 61/28Mbps 1600m -> 54/20Mbps 1800m -> 48/13Mbps 2000m -> 38/9Mbps 2200m -> 35/6Mbps 2400m -> 31/4Mbps Symmetric (Download / Upload) 200m -> 95/99Mbps 400m -> 92/97Mbps 600m -> 81/82Mbps 800m -> 71/70Mbps 1000m -> 60/57Mbps 1200m -> 50/44Mbps 1400m -> 42/33Mbps 1600m -> 37/27Mbps 1800m -> 29/22Mbps 2000m -> 23/21Mbps 2200m -> 19/17Mbps 2400m -> 19/13Mbps |
RJ-11 (Phone-Line) | Asymmetric (Download / Upload) 200m -> 99/63Mbps 400m -> 91/48Mbps 600m -> 71/32Mbps 800m -> 53/18Mbps 1000m -> 38/8Mbps 1200m -> 33/5Mbps 1400m -> 28/2Mbps Symmetric (Download / Upload) 200m -> 91/99Mbps 400m -> 74/79Mbps 600m -> 54/51Mbps 800m -> 38/34Mbps 1000m -> 27/21Mbps 1200m -> 24/15Mbps 1400m -> 21/10Mbps |
Power over Ethernet | |
PoE Standard | IEEE 802.3af Power over Ethernet / PSE |
PoE Type | End-Span |
PoE Power Output | 48V DC Per Port, 350mA. Max. 15.4 Watts |
PoE Pin Assignment | 1/2(+), 3/6(-) |
Standard Conformance | |
Regulation Compliance | FCC Part 15 Class A, CE |
Stability Testing | IEC60068-2-32 (Free Fall) IEC60068-2-27 (Shock) IEC60068-2-6 (Vibration) |
Standards Compliance | IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX IEEE 802.3af Power over Ethernet IEEE 802.3x Full Duplex Pause Frame Flow-Control ITU-T - G.993.1 - G.997.1 - G.993.2 (Profile 17a Support) |
Environment | |
Operating Temperature | -40 ~ 75 Degree C |
Operating Humidity | 5~90%, relative humidity, non-condensing |
Storage Temperature | -40 ~ 85 Degree C |
Storage Humidity | 5~90%, relative humidity, non-condensing |